LEED Green Associate Practice Test
Practise for the LEED Green Associate with 615 exam-style questions, an explanation for every answer and stats that show what to study next.
What is the LEED Green Associate exam?
The LEED Green Associate exam is a 2-hour, 100-question multiple-choice test administered by GBCI, and the current version is based on LEED v5. No experience is required, the standard fee is $250, and you need a score of 170 to pass. Study from v5 material only: practice exams labeled v4 still turn up in searches, and one of USGBC's own prep pages still shows the v4 outline.
This page follows the candidate handbook, marked "Updated September 2026", wherever USGBC pages differ from it. The details below were read on official pages on November 7, 2026, so check fees and policies again before you pay.
Who can take it, and should you?
There is no eligibility prerequisite, but you must agree to GBCI's Disciplinary and Exam Appeals Policy and the credential maintenance requirements. Candidates under 18 need parental consent through GBCI. GBCI recommends prior exposure through courses, volunteering or work, but that is advice and not a condition.
To decide, check whether job postings in your market ask for it and whether your employer will pay. Also consider whether you plan to pursue LEED AP, which requires a current Green Associate credential or the combined exam. No official salary data was found, so be cautious with salary figures you see elsewhere.
LEED Green Associate exam format
| Item | Official detail |
|---|---|
| Questions | 100 multiple choice, one correct answer each |
| Time | 2 hours of testing; plan for 2 hours 20 minutes in total |
| Delivery | Prometric test center, or online through ProProctor |
| Breaks | Test center: allowed, clock keeps running. Remote: not permitted |
| Navigation | Skip, flag and change answers |
| Passing standard | 170 or higher on a 125 to 200 scale |
| Results | Score on screen at the end; dashboard updated within 72 hours |
| Language | English only at present; translated versions expected in 2027 |
The handbook's domain counts total 85, not 100. It confirms that unscored questions are mixed in and not identified, so 85 scored and 15 unscored is a fair inference, though no official sentence states the split. Treat every question as if it counts.
The USGBC credential page lists translation aids in eight languages. The handbook, updated September 2026, says English only and rules out translators and foreign-language dictionaries. If English is not your first language, confirm with GBCI before you book.
What it covers, and how to split study time
The handbook gives question counts for eight domains. It publishes no percentages, so the shares below are worked out from the total of 85. The last column turns each share into time for every 10 hours you plan to study.
| Domain | Questions | Share of 85 | Per 10 hours |
|---|---|---|---|
| LEED Process | 15 | 17.6% | 1 h 45 min |
| Energy and Atmosphere | 15 | 17.6% | 1 h 45 min |
| Materials and Resources | 11 | 12.9% | 1 h 20 min |
| Indoor Environmental Quality | 11 | 12.9% | 1 h 20 min |
| Water Efficiency | 10 | 11.8% | 1 h 10 min |
| Location and Transportation | 9 | 10.6% | 1 h 5 min |
| Sustainable Sites | 8 | 9.4% | 55 min |
| Integrative Process Planning and Assessments | 6 | 7.1% | 40 min |
Use this split as a starting point. It is not an official plan, so move time toward the domains where your practice results are weak.
The domains also ask for different things. LEED Process covers how the system works, including the roles of USGBC and GBCI, review phases and certification levels. Integrative Process is about early assessment, systems thinking, life cycle cost and who belongs on the team. The other six go well past credit names: Energy and Atmosphere, for instance, lists commissioning, renewable energy certificates and refrigerants, while Indoor Environmental Quality lists lighting, sound, thermal conditions and biophilic design.
Do not take your priorities from the LEED scorecard, because it weights things differently. On the v5 New Construction scorecard, Integrative Process is worth 1 point of 110, yet its domain has 6 exam questions. Sustainable Sites has 11 points and Water Efficiency has 9, but water has more questions, 10 against 8. LEED Process has 15 questions and is not a scorecard category at all. Energy and Atmosphere is the one category at the top of both, with the most points (33) and a tie for the most questions (15).
Start with LEED Process, since the other domains assume you know its terms: the rating system families (BD+C, ID+C, O+M), the 40/60 floor area rule for choosing a system, the four certification levels (40, 50, 60 and 80 points) and the three v5 impact areas. Those areas are decarbonization, quality of life, and ecological conservation and restoration. Platinum in v5 also has added requirements, so 80 points alone is not enough.
The handbook says questions test recall, application and analysis, but it gives no split. So practice applying rules to a project: which rating system fits, which site or product qualifies, what a team still has to do.
LEED Green Associate v4 vs v5: which study guide to use
The USGBC exam preparation page, as read on the date above, shows nine knowledge domains and references dated 2011 to 2014, with v4 titles among them. Its "Project Surroundings and Public Outreach" domain does not appear in the handbook's eight. Its study materials include a preparation guide labeled LEED v4 Edition and a 2019 practice exam. Follow the handbook.
The handbook names four exam references: the LEED Core Concepts Guide, 5th edition (2026); Foundations of LEED (2023); the Guide to LEED Certification: Commercial; and the Rating System Selection Guidance. USGBC posts the v5 rating system documents as PDFs, which help you check credit names. The handbook does not list them as exam references, so read them for concepts and do not try to memorize every threshold.
Of VirtuePrep's 20 free practice test questions on this page, 18 were written against the July 2026 BD+C document and sometimes go into that detail. The other 2 use the selection guidance and the certification guide. They are for practice and are not real exam questions. They sample the outline and do not cover it: none touches lighting, sound, biophilic design, outdoor water use or equitable development, so a good result here says nothing about those topics.
Exam cost, rescheduling and retakes
The fee is $250 standard, $200 for USGBC members and $100 for students. The official page shows these fees with a dollar sign and names no currency or local prices, and the student conditions could not be read. Confirm the amount you will be charged and the student conditions before you register. If your organization is a USGBC member, link that status to your USGBC account before you register to get the member price. The handbook also notes VA reimbursement of up to $2,000 under the GI Bill for those who qualify.
One fee covers one attempt, and that attempt must fall within 12 months of your registration date.
| Days before your appointment | Reschedule or cancel fee |
|---|---|
| 46 or more | None |
| 30 to 45 | $30 |
| 4 to 29 | $60 |
| 0 to 3 | Not allowed |
If you miss the appointment, you forfeit the full fee. To switch between test center and online delivery, you have to cancel and rebook, so look at the fee table before you do. If you fail, register and pay again. After three failed attempts within 12 months, you wait 90 calendar days before registering again.
Appointments are scheduled through Prometric, and the handbook shows no fixed exam dates.
What to do next
- Read the handbook's exam specifications so that you are working from the v5 outline.
- Work through the free questions on this page and note your weak domains.
- Set your study split from the table above, then shift time toward those domains.
- Choose test center or online early. Switching later means canceling first, and remote exams allow no breaks. On an employer's computer, a remote exam requires Administrator rights on the device.
- Check that the first and last name on your registration exactly match the ID you will show. If they do not, you cannot test, and GBCI needs at least 10 business days' notice to change it, or you risk losing the fee.
After you pass, plan for 15 continuing education hours every 2 years, 3 of them LEED-specific. Other exams are listed on the VirtuePrep exams page.
20 free LEED Green Associate practice questions
Answer each one yourself, then open the answer. No account needed. These are study questions, not real exam questions.
-
A developer is building a 12-story office tower and wants one LEED v5 certification for the whole building. At certification, the structure, enclosure and main mechanical systems will be finished, but tenant floors making up 70 percent of the gross floor area will have no fit-out. Which rating system fits this project?
- BD+C: New Construction and Major Renovations
- ID+C: Commercial Interiors
- BD+C: Core and Shell Development
- O+M: Existing Buildings
Show answer
Answer: C. Core and Shell applies when at least 40 percent of gross floor area is incomplete at certification, and here 70 percent is. New Construction needs at least 60 percent complete. ID+C Commercial Interiors is for interior work with no shell or site work in scope, and O+M needs a building that has been fully operational and occupied for at least a year.
-
A LEED v5 New Construction project is forecast at 84 points. It has 8 Enhanced Energy Efficiency points, 4 Electrification points, renewable energy covering all site energy use and a 20 percent embodied carbon reduction. Gas boilers remain for very cold days. What still stands between this project and Platinum?
- Reaching at least 90 total points by adding credits in any category
- Removing on-site combustion to earn all 5 Electrification points
- Achieving a 40 percent embodied carbon reduction instead of 20 percent
- Moving its renewable energy supply entirely to on-site Tier 1 generation
Show answer
Answer: B. Platinum starts at 80 points, but v5 adds specific requirements. For New Construction, these include all 5 Electrification points, which come only from the option with no on-site combustion apart from emergency support systems. The project already meets the other three added requirements, and the renewable requirement can be met with any mix of tiers.
-
A project's final review comes back with one credit denied, which leaves it two points short of Gold. The team now has new documentation that it believes supports the credit, while the owner is eager to accept the result and announce certification. What should the team do first?
- Revise the application and submit a supplemental (appeal) review before accepting
- Accept the review now and send the new documents to GBCI for an appeal afterward
- Ask GBCI to reopen the preliminary review so that the credit can be resubmitted there
- Accept the review now and move the denied credit into a precertification application
Show answer
Answer: A. After final review, a team can either accept the results or revise and resubmit through a supplemental (appeal) review. Accepting ends the ability to appeal or contest individual credit decisions, so the appeal must come first. There is no cap on the number of appeal reviews, although they carry a fee.
-
An owner plans to hold the project's only design charrette at the end of design development, attended by the architect and the mechanical engineer. Project goals would be set once construction documents are underway. Which change best brings this plan in line with the v5 Integrative Design Process credit?
- Keep the timing, and invite the contractor, energy modeler and owner's representative too
- Keep the attendees, and repeat the session at the start of construction
- Replace the session with a written systems report from the mechanical engineer
- Move it to predesign or early design, with the owner and at least four key perspectives
Show answer
Answer: D. The credit calls for a charrette during predesign or early in design, with the owner or a representative and participants from at least four key perspectives. Goal setting comes early too: the goals address the three LEED v5 impact areas and go into the owner's project requirements.
Source: LEED v5 BD+C Rating System, July 2026 edition, IPc1, p. 12
-
A team is comparing four previously undeveloped parcels and wants to earn the Sensitive Land Protection credit. All four lie outside any floodplain and have no steep slopes. Which parcel should it choose?
- Parcel A: prime farmland, no listed species, footprint 200 feet from any wetland or lake
- Parcel B: no mapped farmland, no listed species, footprint 200 feet from any wetland or lake
- Parcel C: no mapped farmland, no listed species, footprint 40 feet from a lake
- Parcel D: no mapped farmland, state-listed endangered species, footprint 200 feet from any wetland or lake
Show answer
Answer: B. For previously undeveloped land, the development footprint must avoid prime farmland, floodplains, notable habitat, areas within 100 feet of a water body and areas within 50 feet of a wetland, apart from minor improvements near water. Only Parcel B avoids all of these. Each of the others fails on one point: farmland, distance to a water body, or habitat.
Source: LEED v5 BD+C Rating System, July 2026 edition, LTc1, p. 16 to 17
-
An office project has completed its transportation demand management assessment. The base ratio gives 200 parking spaces, and the design provides 130. The owner also charges a monthly parking fee at the local market rate. The credit gives 1, 2 or 3 points for 30, 60 or 100 percent below the base ratio, and 2 points for a market-rate fee. How many points does the parking strategy earn?
- 1 point
- 2 points
- 3 points
- 4 points
Show answer
Answer: C. Providing 130 of 200 spaces is a 35 percent reduction, which reaches the 30 percent tier for 1 point but not the 60 percent tier. The market-rate fee adds 2 points, and the two paths can be combined, for a total of 3.
Source: LEED v5 BD+C Rating System, July 2026 edition, LTc4, p. 28 to 29
-
A suburban office project, not a zero lot line site, is pursuing the percentile rainfall option of the Rainwater Management credit. Which plan fits the credit?
- Direct roof and paving runoff into rain gardens and bioswales that infiltrate it on site
- Hold runoff in an underground vault that releases it slowly into the storm sewer
- Run runoff through a filter unit that cleans it before it enters the storm sewer
- Pay into a municipal retention pond that serves other properties across the district
Show answer
Answer: A. The credit requires the percentile event volume to be retained on site, by infiltration, evapotranspiration, or collection and reuse, using low-impact development and green infrastructure practices. Slow release to a sewer and filtering before discharge both still send the water away. Combining on-site and off-site strategies is allowed for zero lot line projects only.
Source: LEED v5 BD+C Rating System, July 2026 edition, SSc3, p. 42 to 43
-
A team is choosing a membrane for a low-sloped roof under the Heat Island Reduction credit. The minimum is an aged SRI of 64, and an initial SRI of 82 applies only when no aged value is available. Which product qualifies?
- Product A: initial SRI 88, aged SRI 60
- Product B: initial SRI 80, no aged value published
- Product C: initial SRI 84, aged SRI 62
- Product D: initial SRI 78, aged SRI 66
Show answer
Answer: D. Where an aged value exists, it is the one that counts, and only Product D reaches 64. The high initial values of Products A and C do not help, because their aged values fall short. Product B has no aged value, so it is judged on the initial figure and misses 82.
Source: LEED v5 BD+C Rating System, July 2026 edition, SSc5, p. 48 to 49
-
A project specifies dual-flush toilets at 1.6 gallons per flush on full flush and 0.8 on low flush, with an expected weighted average of 1.1. All other fixtures meet the prescriptive limits. The prescriptive maximum for toilets under Minimum Water Efficiency is 1.28. Can the team use the prescriptive path?
- Yes, because the weighted average is below the limit
- Yes, because the low-flush volume is below the limit
- No, because the full-flush volume is above the limit
- No, because the path excludes all dual-flush toilets
Show answer
Answer: C. For dual-flush toilets, the full-flush volume must be 1.28 gallons per flush or less, and a weighted average cannot be used. Dual-flush models are allowed if they meet that figure. This model would need a lower full-flush volume, or the team would have to choose a different toilet.
Source: LEED v5 BD+C Rating System, July 2026 edition, WEp2, p. 56
-
A new office building draws on city water and a rainwater cistern, and the two sources join before a single permanent meter. What does the Water Metering and Reporting prerequisite require the team to change?
- Meter the rainwater separately from the city water and report use for each source
- Keep the one meter and estimate the rainwater share from the size of the cistern
- Keep the one meter and drop rainwater from reports because it is not potable water
- Replace the main meter with individual submeters on every fixture in the building
Show answer
Answer: A. The prerequisite requires whole-project use to be reported for each type of water source, with alternative sources metered separately from municipal potable water. The team also commits to sharing whole-project data with USGBC at least annually for five years, or until ownership or lessee changes. Submeters belong to an optional credit.
Source: LEED v5 BD+C Rating System, July 2026 edition, WEp1, p. 54, and WEc1, p. 59
-
An owner plans to wait until the construction contract is signed before naming a commissioning provider, and has in mind a firm that has commissioned one project of similar size. What does the Fundamental Commissioning prerequisite call for?
- The planned timing and firm, as long as the firm samples 10 percent of contractor documents
- A provider named by the end of design development, with at least two projects of equal or larger scope
- The planned timing, but with a firm that has at least two projects of equal or larger scope
- The planned firm, but named on or before the first day of construction
Show answer
Answer: B. The owner must designate the provider by the end of the design development phase, and the provider needs experience on two or more projects at least as large and complex. The provider also assists with the owner's project requirements in predesign or as early as possible, so waiting for construction misses that work.
Source: LEED v5 BD+C Rating System, July 2026 edition, EAp3, p. 81 to 82
-
A project has a rooftop photovoltaic array covering 12 percent of annual site energy. To help pay for it, the owner plans to sell the array's renewable energy certificates to an outside buyer. Can this generation count toward the Renewable Energy credit?
- Yes, because on-site generation always counts as Tier 1 renewable energy
- No, because Tier 1 generation must cover at least 20 percent of site energy
- Yes, but only as Tier 3, because the certificates would leave the project
- No, because the certificates must be retired on behalf of the LEED project
Show answer
Answer: D. All environmental attributes tied to the renewable generation must be retired on behalf of the project for the energy to contribute to the credit. The roof location makes the array eligible as Tier 1, and 12 percent clears the 5 percent needed for 1 point, but selling the certificates transfers the attributes, so the generation cannot contribute.
Source: LEED v5 BD+C Rating System, July 2026 edition, EAc4, p. 109 to 111
-
A new office building will use HVAC equipment with a refrigerant that has a global warming potential of 1,300 and contains no HCFCs. Under the Fundamental Refrigerant Management prerequisite, what must the team do about this refrigerant?
- Replace it, because refrigerants above a GWP of 700 are prohibited outright
- Install a different system, because the prerequisite requires no refrigerants
- Evaluate available alternatives during design and record it in the inventory
- Take no action, because the prerequisite restricts only HCFC refrigerants
Show answer
Answer: C. Refrigerants above a GWP of 700 are not banned, but the team must evaluate available alternatives during design. The inventory must list the type, GWP and amount for each piece of equipment, and equipment must be leak checked before substantial completion. Avoiding refrigerants entirely is one option, not a requirement.
Source: LEED v5 BD+C Rating System, July 2026 edition, EAp5, p. 85
-
A New Construction team is pursuing the Reduce Peak Thermal Loads credit to lower the demand its building places on the grid. Which plan fits this credit?
- Test envelope air leakage against the cap and balance ventilation and exhaust flows
- Add on-site batteries and shift the building's cooling operation to off-peak hours
- Accept a weaker envelope and offset the difference with higher-efficiency chillers
- Buy off-site renewable electricity to cover the building's peak demand months
Show answer
Answer: A. The credit's first option combines a measured air leakage test with ventilation and exhaust airflows designed within 10 percent of each other. Envelope efficiency cannot be traded off against other building systems. On-site storage falls under the Grid Interactive credit and procurement under Renewable Energy. Those change when or how energy is supplied, and the thermal load itself stays the same.
Source: LEED v5 BD+C Rating System, July 2026 edition, EAc2, p. 92 to 93, EAc4, p. 109, and EAc6, p. 120
-
A mid-rise project has a detached parking structure inside its LEED boundary. Its embodied carbon calculation covers the main building's structure and enclosure at cradle-to-gate, and it names the top three carbon sources with strategies for each. What is still missing for the Quantify and Assess Embodied Carbon prerequisite?
- Interior finishes and furniture across all floors of the main building
- The parking structure and the project's hardscape materials
- End-of-life emissions for each of the materials in the calculation
- A 20 percent reduction against a baseline for the whole project
Show answer
Answer: B. The prerequisite covers structure, enclosure and hardscape, and it specifically includes ancillary structures inside the LEED boundary. It asks for cradle-to-gate results, not end-of-life figures. This prerequisite only measures and assesses. Reductions earn points under a separate credit, where 20 percent is a Platinum requirement.
Source: LEED v5 BD+C Rating System, July 2026 edition, MRp2, p. 128, and Appendix I, p. 174
-
A contractor tracks these construction and demolition materials: 500 tons source-separated and sent to single-material recyclers; 200 tons of mixed material sent to an unverified processor, which the credit caps at 35 percent; 150 tons sent to incineration with energy recovery; 150 tons landfilled; and 400 tons of excavated soil hauled away. What diversion rate can the project report?
- 41 percent
- 57 percent
- 69 percent
- 85 percent
Show answer
Answer: B. Excavated soil is excluded from the calculation, which leaves 1,000 tons. Source-separated material counts at 100 percent (500 tons) and the mixed load at 35 percent (70 tons). Incineration with energy recovery counts as waste, as does landfill, so 570 of 1,000 tons is 57 percent.
Source: LEED v5 BD+C Rating System, July 2026 edition, MRc5, p. 146 to 147
-
A flooring product worth $40,000 has product documents showing Level 2 in human health and Level 1 in climate health. Under Building Product Selection and Procurement, level scores of 1, 2 or 3 are added across criteria areas, up to 5 per product, and the total multiplies the product's value. What adjusted value does this flooring have?
- $40,000
- $80,000
- $120,000
- $200,000
Show answer
Answer: C. The level scores add up to a multi-attribute score of 3 (2 plus 1). Multiplying the $40,000 value by 3 gives $120,000. Using only the higher level would give $80,000, and $200,000 would apply only to a product at the maximum score of 5.
Source: LEED v5 BD+C Rating System, July 2026 edition, MRc4, p. 143 to 145
-
An office design places an outdoor smoking shelter 40 feet from the main entrance and 12 feet from an operable window in a side wing. Local code does not limit the distance. Does this meet the No Smoking or Vehicle Idling prerequisite?
- Yes, because it is over 25 feet from the main entrance
- Yes, because the shelter is an outdoor designated area
- No, because smoking must be banned across all office sites
- No, because it is under 25 feet from an operable window
Show answer
Answer: D. A designated outdoor smoking area must be at least 25 feet from all entries, outdoor air intakes and operable windows, or the maximum extent local codes allow. Meeting the distance at the entrance is not enough. A site-wide smoking ban applies to school projects, not to this office.
Source: LEED v5 BD+C Rating System, July 2026 edition, EQp3, p. 153
-
Late in construction, the contractor says the permanent air handlers must run to keep newly installed finishes dry. Under the Construction Management prerequisite, how should the team handle this?
- Keep proper filtration during use, then replace all filter media before occupancy
- Run the units with no filter media, then install new filters right before occupancy
- Keep proper filtration during use, then leave the same media in place after turnover
- Run the units freely, because the prerequisite covers portable equipment only
Show answer
Answer: A. The prerequisite discourages running permanent equipment during construction, but if it must be used, proper filtration has to be maintained. All air filtration media must be replaced after construction and before occupancy, and testing and balancing must be confirmed as complete with the new filtration.
Source: LEED v5 BD+C Rating System, July 2026 edition, EQp1, p. 148
-
A project meets its local accessibility codes and has 12 strategies from the Accessibility and Inclusion credit's list, such as nonslip flooring and tactile maps. Local code already requires 5 of them. The credit asks for at least 10 listed strategies that go beyond code. What must the project do to earn it?
- Nothing further, because 12 listed strategies exceed the minimum
- Add 5 strategies beyond code, to replace the ones code requires
- Add 3 strategies beyond code, for a total of 10
- Add one strategy from each group, whatever the total
Show answer
Answer: C. Only strategies that go beyond the locally applicable code count toward the 10, so the project has 7 and must add 3. Meeting local accessibility codes is a separate requirement. The requirement is a total count, and the credit listing does not ask for one from each group.
Source: LEED v5 BD+C Rating System, July 2026 edition, EQc3, p. 163 to 164
What you get with VirtuePrep LEED Green Associate prep
- 615 practice questions built around the topics the LEED Green Associate tests.
- An explanation for every answer, so each mistake teaches you something.
- Stats and history that show your weakest topics first.
- Web, iPhone and Android, so you can study wherever you have ten minutes.
LEED Green Associate practice test questions people ask
How many questions are on the LEED Green Associate exam?
Is the LEED Green Associate exam multiple choice?
Is the LEED Green Associate exam online?
What is the LEED Green Associate passing score?
How much does the LEED Green Associate exam cost?
Is the LEED Green Associate exam hard?
How long should you study for the LEED Green Associate exam?
What is the LEED Green Associate pass rate?
Does LEED Green Associate expire?
How do you become a LEED Green Associate?
What is the difference between LEED Green Associate and LEED AP?
Is LEED Green Associate worth it?
Sources
- LEED Green Associate Candidate Handbook, updated September 2026 (GBCI)
- LEED Green Associate credential page, fees and renewal (USGBC)
- LEED credentials overview, continuing education hours (USGBC)
- LEED AP credential page (USGBC)
- Exam preparation page, showing the v4 outline (USGBC)
- LEED v5 BD+C rating system, July 2026 edition (USGBC)
- Rating System Selection Guidance (USGBC)
- Guide to LEED Certification: Commercial (USGBC)
- LEED v5 overview (USGBC)
VirtuePrep is not affiliated with or endorsed by the organisation that runs the LEED Green Associate. Exam names are trademarks of their owners. Practice questions are written for study and are not real exam questions. Page updated 2026-11-07.
More Building and Construction exams
EPA 608
The EPA 608 exam can look tougher than it is.
Building and ConstructionFE (NCEES)
The FE exam can feel like a punch to the gut when you first start studying.
Building and ConstructionJourneyman Electrician
The Journeyman test hits you with way more than you expect the first time you look at it.